MyJournals Home  

RSS FeedsEvaluation of a new pocket echoscopic device for focused-cardiac ultrasonography in emergency setting (Critical Care)

 
 

14 may 2012 16:50:12

 
Evaluation of a new pocket echoscopic device for focused-cardiac ultrasonography in emergency setting (Critical Care)
 


IntroductionIn the emergency setting, focused cardiac ultrasound has become a fundamental tool for diagnostic, initiate emergency treatment and triage decisions. A new ultra-miniaturized pocket ultrasound device (PUD) may be suited in this specific setting. Therefore, we aimed to compare the diagnostic ability of an ultra-miniaturized ultrasound device (VscanTM, GE Healthcare, Wauwatosa, WI) and of a conventional high-quality echocardiography system (Vivid S5TM, GE Healthcare) for a cardiac focused ultrasonography in patients admitted in emergency department. Methods: During 4 months, patients admitted to our emergency department and requiring transthoracic echocardiography (TTE) were included in this single-center, prospective and observational study. Patients underwent TTE using pocket ultrasound device (PUD) and conventional echocardiography system. Each examination was performed independently by a physician experienced in echocardiography, unaware of the results found by the alternative device. During the focused cardiac echocardiography, the following parameters were assessed: global cardiac systolic function, identification of ventricular enlargement or hypertrophy, assessment for pericardial effusion and estimation of the size and the respiratory changes of the inferior vena cava (IVC) diameter. Results: One hundred and fifty one (151) patients were analysed. Using the tested PUD, the image quality was sufficient to perform focused cardiac ultrasonography in all patients. Examination using PUD adequately qualified with a very good agreement global left ventricular systolic dysfunction (kappa=0.87; 95%CI: 0.76-0.97), severe right ventricular dilation (kappa=0.87; 95%CI: 0.71-1.00), inferior vena cava dilation (kappa=0.90; 95%CI: 0.80-1.00), respiratory induced variations in inferior vena cava size in spontaneous breathing (kappa=0.84; 95%CI: 0.71-0.98), pericardial effusion (kappa=0.75; 95%CI: 0.55-0.95) and compressive pericardial effusion (kappa=1.00; 95%CI: 1.00-1.00). Conclusions: In emergency setting, this new ultraportable echoscope was reliable for the real-time detection of focused cardiac abnormalities.


 
302 viewsCategory: Medicine
 
Increased type II collagen cleavage by cathepsin K and collagenase activities with aging and osteoarthritis in human articular cartilage (Arthritis Research & Therapy)
A measure for quantifying the impact of housing quality on respiratory health: a cross-sectional study (Environmental Health)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Medicine


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten