MyJournals Home  

RSS FeedsSensors, Vol. 19, Pages 5339: Error Analysis and Modeling for an Absolute Capacitive Displacement Measuring System with High Accuracy and Long Range (Sensors)

 
 

4 december 2019 14:00:06

 
Sensors, Vol. 19, Pages 5339: Error Analysis and Modeling for an Absolute Capacitive Displacement Measuring System with High Accuracy and Long Range (Sensors)
 


We proposed a novel kind of absolute capacitive grating displacement measuring system with both high accuracy and long range in a previous article. The measuring system includes both a MOVER and a STATOR, the contact surfaces of which are coated by a thin layer of dielectric film with a low friction coefficient and high hardness. The measuring system works in contact mode to minimize the gap changes. This paper presents a theoretical analysis of the influence of some factors, including fabrication errors, installation errors, and environment disturbance, on measurement signals. The measuring signal model was modified according to the analysis. The signal processing methods were investigated to improve the signal sensitivity and signal-to-noise ratio (SNR). The displacement calculation model shows that the design of orthogonal signals can solve the dead-zone problem. Absolute displacement was obtained by a simple method using two coarse signals and highly accurate displacement was further obtained while using two fine signals with the help of absolute information. According to the displacement calculation model and error analysis, the error in fine calculation functions mainly determines the model’s accuracy and is locally affected by coarse calculation functions. It was also determined that amplitude differences, non-orthogonality, and signal offsets are not related to the accuracy of the displacement calculation model. The experiments were carried out to confirm the abovementioned theoretical analysis. The experimental results show that the displacement resolution and error in the displacement calculation model reach ±4.8 nm and ±34 nm, respectively, in the displacement range of 5 mm. The experiments and the theoretical analyses both indicate that our proposed measuring system has great potential for achieving an accuracy of tens of nanometers and a range of hundreds of millimeters.


 
235 viewsCategory: Chemistry, Physics
 
Sensors, Vol. 19, Pages 5340: In Situ Diagnosis of Industrial Motors by Using Vision-Based Smart Sensing Technology (Sensors)
Sensors, Vol. 19, Pages 5338: Beam Search Algorithm for Ship Anti-Collision Trajectory Planning (Sensors)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Physics


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten