MyJournals Home  

RSS FeedsRemote Sensing, Vol. 14, Pages 3898: Laboratory Calibration of an Ultraviolet–Visible Imaging Spectropolarimeter (Remote Sensing)

 
 

11 august 2022 14:24:36

 
Remote Sensing, Vol. 14, Pages 3898: Laboratory Calibration of an Ultraviolet–Visible Imaging Spectropolarimeter (Remote Sensing)
 


The ultraviolet–visible imaging spectropolarimeter (UVISP), developed by the Anhui Institute of Optics and Fine Mechanics (AIOFM), Chinese Academy of Science (CAS), is a dual-beam snapshot instrument for measuring the spectral, radiometric, and linear polarization information of absorbing aerosol in a wavelength range from 340 to 520 nm. In this paper, we propose a complete set of calibration methods for UVISP to ensure the accuracy of the measured radiation polarization data, thus guaranteeing the reliability of inversion results. In geometric calibration, we complete the assignment of the field of view (FOV) angle to each pixel of the detector using a high precision turntable and parallel light source. In addition, the geometric calibration accuracy of the S beam and P beam is also analyzed. The results show that the residuals of all row pixels are less than 0.12°. Based on geometric calibration, a spectral calibration is conducted at each spectrum of the S beam and P beam for the given FOV, and the relation between the wavelength and pixel is obtained by a linear fitting procedure. For radiometric calibration, the uniformity of spectral responsivity is corrected, and the function between spectral radiance and output digital data is established. To improve the accuracy of the polarimetric measurement, a polarimetric calibration is proposed, and validated experimental results show that the root mean square (RMS) errors for the demodulated value are all within 0.011 for the input linear polarized light with different angles of linear polarization (AoLPs). Finally, field measurements are conducted, and the absolute deviations are all within 0.01 when the UVISP and CE-318 sun–sky polarimetric radiometer (CE318N) simultaneously measure the degree of linear polarization (DoLP) of the sky at different zenith angles. These experimental results demonstrate the efficiency and accuracy of the proposed calibration methods.


 
90 viewsCategory: Geology, Physics
 
Remote Sensing, Vol. 14, Pages 3896: Retrieval of Suspended Sediment Concentrations in the Pearl River Estuary Using Multi-Source Satellite Imagery (Remote Sensing)
Remote Sensing, Vol. 14, Pages 3890: NeXtNow: A Convolutional Deep Learning Model for the Prediction of Weather Radar Data for Nowcasting Purposes (Remote Sensing)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Physics


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten