MyJournals Home  

RSS FeedsEffect of treatment with an overheated dry-saturated steam vapour disinfection system on multidrug and extensively drug-resistant nosocomial pathogens and comparison with sodium hypochlorite activity (BMC Research Notes)

 
 

9 october 2015 20:20:50

 
Effect of treatment with an overheated dry-saturated steam vapour disinfection system on multidrug and extensively drug-resistant nosocomial pathogens and comparison with sodium hypochlorite activity (BMC Research Notes)
 


Background: The development of portable steam generators has made disinfection of the environment more practical. This study assessed the “in vitro” ability of an overheated dry-saturated steam vapour system to kill multidrug and extensively-drug resistant nosocomial pathogens, defining the antimicrobial spectrum and the contact times compared with the activity of sodium hypochlorite. Methods: The antibacterial efficacy of the overheated dry-saturated steam vapour system and of sodium hypochlorite against nosocomial pathogen isolates: extensively drug-resistant Acinetobacter baumannii, Pseudomonas aeruginosa, carbapenemase-producing Klebsiella pneumoniae, methicillin-resistant Staphylococcus aureus, high-level aminoglycoside-resistant Enterococcus faecalis, Candida parapsilosis and Aspergillus fumigatus were assessed using a surface time-kill test carried out on glass surfaces, with or without bovine serum albumin (BSA). Results: The bactericidal activity of the overheated dry-saturated steam vapour system was observed at 180 °C after 5 min contact with or without BSA, using an initial inoculum of 10 9 CFU/mL. To reduce C. parapsilosis and A. fumigatus counts (from 10 7 CFU/mL), a longer contact time was necessary (7 min). In vitro tests with sodium hypochlorite at 5 % in the absence of an organic substance also resulted in an overall reduction in bacterial counts (from 10 9 CFU/mL) after 5 min of treatment. For mycotic challenge (10 7 CFU/mL), a longer contact time was necessary (7 min). In the presence of an organic substance, after 5 min, the hypochlorite reduced the viable count from 10 9 to 10 5 CFU/mL for all bacterial strains except E. faecalis that showed a reduction of 2 log units (10 9 to 10 7 CFU/mL). For C. parapsilosis and A. fumigatus, a 2 log unit reduction was observed after 7 min. Conclusions: Steam disinfection of environmental surfaces using a portable steam generator is a practical and effective method that is not affected by the presence of organic matter.


 
161 viewsCategory: General, Biology, Medicine
 
Respondent-driven sampling among gay and bisexual men: experiences from a New Zealand pilot study (BMC Research Notes)
Acceptance and effectiveness for learning of a simulation manikin for suprapubic aspiration in toddlers constructed with simple means (BMC Research Notes)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Medicine


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten