MyJournals Home  

RSS FeedsSensors, Vol. 18, Pages 1996: A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery (Sensors)

 
 

26 june 2018 10:17:02

 
Sensors, Vol. 18, Pages 1996: A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery (Sensors)
 


Radiometric calibration for imaging sensors is a crucial procedure to ensure imagery quality. One of the challenges in relative radiometric calibration is to correct detector-level artifacts due to the fluctuation in discrepant responses (spatial) and electronic instability (temporal). In this paper, the integration of the empirical mode decomposition (EMD) with Hilbert-Huang transform (HHT) in relative radiometric calibration was explored for a new sensor, FS-5 RSI (remote sensing instrument onboard the FORMOSAT-5 satellite). The key intrinsic mode functions (IMFs) analyzed by HHT were examined with the pre-flight datasets of the FS-5 RSI in temporal and spatial variations. The results show that the EMD-HHT method can stabilize and improve the radiometric quality of the FS-5 imagery as well as boost its application ability to a new level. It is noticed that the IMFs of the spatial variation would be disturbed by the instability of the temporal variation. The relative response discrepancies among detector chips can be well calibrated after considering the temporal effect. Taking a test imagery dataset of gain setting G2 as an example, the standard deviation (STD) of the discrepancy in the digital number after calibration was dramatically scaled down compared to the original ones (e.g., PAN: 66.31 to 1.85; B1: 54.19 to 1.90; B2: 36.50 to 1.49; B3: 32.43 to 1.56; B4: 37.67 to 1.20). The good performance of pre-flight imagery indicates that the EMD-HHT approach could be highly practical to the on-orbit relative radiometric calibration of the FS-5 RSI sensor and is applicable to other optical sensors. To our knowledge, the proposed EMD-HHT approach is used for the first time to explore relative radiometric calibration for optical sensors.


 
73 viewsCategory: Chemistry, Physics
 
Sensors, Vol. 18, Pages 1997: Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (Sensors)
Sensors, Vol. 18, Pages 1995: GSOS-ELM: An RFID-Based Indoor Localization System Using GSO Method and Semi-Supervised Online Sequential ELM (Sensors)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Physics


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten