MyJournals Home  

RSS FeedsEnergies, Vol. 11, Pages 3537: Experimental Comparison of Three Real-Time Optimization Strategies Applied to Renewable/ FC-Based Hybrid Power Systems Based on Load-Following Control (Energies)

 
 

20 december 2018 09:00:17

 
Energies, Vol. 11, Pages 3537: Experimental Comparison of Three Real-Time Optimization Strategies Applied to Renewable/ FC-Based Hybrid Power Systems Based on Load-Following Control (Energies)
 


Besides three different real-time optimization strategies analyzed for the Renewable/ Fuel Cell Hybrid Power Systems (REW/FC-HPS) based on load-following (LFW) control, a short but critical assessment of the Real-Time Optimization (RTO) strategies is presented in this paper. The advantage of power flow balance on the DC bus through the FC net power generated using the LFW control instead of using the batteries` stack is highlighted in this study. As LFW control consequence, the battery operates in charge-sustained mode and many advantages can be exploited in practice such as: reducing the size of the battery and maintenance cost, canceling the monitoring condition of the battery state-of-charge etc. The optimization of three FC-HPSs topologies based on appropriate RTO strategy is performed here using indicators such as fuel economy, fuel consumption efficiency, and FC electrical efficiency. The challenging task to optimize operation of the FC-HPS under unknown profile of the load demand is approached using an optimization function based on linear mix of the FC net power and the fuel consumption through the weighting coefficients knet and kfuel. If optimum values are chosen, then a RTO switching strategy can improve even further the fuel economy over the entire range of load.


 
75 viewsCategory: Biophysics, Biotechnology, Physics
 
Energies, Vol. 11, Pages 3538: Development and Test of Solutions to Enlarge the Power of PV Irrigation and Application to a 140 kW PV-Diesel Representative Case (Energies)
Energies, Vol. 11, Pages 3536: Experimental Study for the Assessment of the Measurement Uncertainty Associated with Electric Powertrain Efficiency Using the Back-to-Back Direct Method (Energies)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Physics


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten