RSS FeedsSustainability, Vol. 11, Pages 5730: The Impact of Air Well Geometry in a Malaysian Single Storey Terraced House (Sustainability)

 
 

16 october 2019 23:04:48

 
Sustainability, Vol. 11, Pages 5730: The Impact of Air Well Geometry in a Malaysian Single Storey Terraced House (Sustainability)
 


In Malaysia, terraced housing hardly provides thermal comfort to the occupants. More often than not, mechanical cooling, which is an energy consuming component, contributes to outdoor heat dissipation that leads to an urban heat island effect. Alternatively, encouraging natural ventilation can eliminate heat from the indoor environment. Unfortunately, with static outdoor air conditioning and lack of windows in terraced houses, the conventional ventilation technique does not work well, even for houses with an air well. Hence, this research investigated ways to maximize natural ventilation in terraced housing by exploring the air well configurations. By adopting an existing single storey terraced house with an air well, located in Kuching, Sarawak, the existing indoor environmental conditions and thermal performance were investigated and monitored using scientific equipment, namely HOBO U12 air temperature and air humidity, the HOBO U12 anemometer and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter. For this parametric study, the DesignBuilder software was utilized. The field study illustrated that there is a need to improve indoor thermal comfort. Thus, the study further proposes improvement strategies to the existing case study house. The proposition was to turn the existing air well into a solar chimney taking into account advantages of constant and available solar radiation for stack ventilation. The results suggest that the enhanced air well was able to improve the indoor room air velocity and reduce air temperature. The enhanced air well with 3.5 m height, 1.0 m air gap width, 2.0 m length was able to induce higher air velocity. During the highest air temperature hour, the indoor air velocity in existing test room increased from 0.02 m/s in the existing condition to 0.29 m/s in the hottest day with 2.06 °C air temperature reduction. The findings revealed that the proposed air well could enhance the thermal and ventilation performance under the Malaysia tropical climate.


 
206 viewsCategory: Ecology
 
Sustainability, Vol. 11, Pages 5731: Sustainable Construction Project Management (SCPM) Evaluation--A Case Study of the Guangzhou Metro Line-7, PR China (Sustainability)
Sustainability, Vol. 11, Pages 5729: Characterizing the Sharing Economy State of the Research: A Systematic Map (Sustainability)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Ecology


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten