MyJournals Home  

RSS FeedsMolecules, Vol. 24, Pages 3664: Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of ?-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry (Molecules)

 
 

11 october 2019 14:02:14

 
Molecules, Vol. 24, Pages 3664: Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of ?-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry (Molecules)
 


A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol, and metoprolol in human oral fluid samples, which were subsequently detected by liquid chromatography tandem mass spectrometry (LC-MS/MS). Experimental parameters affecting the extraction protocol including sample pH, extraction time, desorption time, appropriate desorption solvent, and salt addition were optimized. Method validation for the detection from oral fluid samples was performed following FDA (Food and Drug Administration) guidelines on bioanalytical method validation. Calibration curves ranging from 5.0 to 2000 nmol L−1 for acebutolol and 25.0 to 2000 nmol L−1 for metoprolol were used. The values for the coefficient of determination (R2) were found to be 0.998 and 0.996 (n = 3) for acebutolol and metoprolol, respectively. The recovery of analytes during extraction was 80.0% for acebutolol and 62.0% for metoprolol, respectively. The limit of detections (LODs) were 1.25, 8.00 nmol L−1 for acebutolol and metoprolol and the lower limit of quantifications (LLOQ) were 5.00 nmol L−1 for acebutolol and 25.0 nmol L−1 for metoprolol. Validation experiments conducted with quality control (QC) samples demonstrated method accuracy between 80.0% to 97.0% for acebutolol and from 95.0% to 109.0% for metoprolol. The inter-day precision for QC samples ranged from 3.6% to 12.9% for acebutolol and 9.5% to 11.3% for metoprolol. Additionally, the GO/PEG-stick was demonstrated to be reusable, with the same stick observed to be viable for more than 10 extractions from oral fluid samples.


 
147 viewsCategory: Biochemistry, Chemistry, Molecular Biology
 
Molecules, Vol. 24, Pages 3659: Penfluridol as a Candidate of Drug Repurposing for Anticancer Agent (Molecules)
Molecules, Vol. 24, Pages 3663: Design, Synthesis and Investigation of the Potential Anti-Inflammatory Activity of 7-O-Amide Hesperetin Derivatives (Molecules)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Molecular Biology


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten