MyJournals Home  

RSS FeedsSustainability, Vol. 12, Pages 1708: Study on the Influence of Air Tightness of the Building Envelope on Indoor Particle Concentration (Sustainability)

 
 

25 february 2020 18:03:59

 
Sustainability, Vol. 12, Pages 1708: Study on the Influence of Air Tightness of the Building Envelope on Indoor Particle Concentration (Sustainability)
 


In order to grasp the building palisade structure tightness of indoor particulate matter mass concentration based on the particle penetration mechanism and settlement characteristics, this article analyzes the measurements of two different types of building air tightness of a Shenyang university office building in terms of indoor and outdoor particulate matter mass concentration levels from 2016-1-09 to 1-22, 2016-7-18 to 8-03, and 2017-2-28 to 3-13. The building outside the closed window that had no indoor source condition, the indoor office building and outdoor particle mass concentration, and the aperture size and shape of the envelope were analyzed to carry on the numerical simulation research by Fluent software, which was then analyzed; the results reveal that the measuring point of the I/O ratio is less than point B of the I/O ratio, measurement points of A linear regression fitting degree is lower than the fit of the measuring point B, and the causes for the measuring point A tightness (level 8) is superior to the measuring point B (level 4). When the gap height h is greater than 0.5 mm, the penetration rate of particles within the range of 0.25–2.5 μm particle size is close to 1. In different gap depths, the penetration rate of particles within the range of 0.1–1 μm particle size was close to 1. In diverse pressure difference, the 0.25–2.5 μm particles within the scope of penetration rate P is close to 1, the gap on both sides of the differential value ΔP; the greater the particle, the higher penetration rate. The larger the right-angle number of gap n, the lower the penetration rate of particles. The L-shaped gap and U-shaped gap have significantly better barrier effects in larger and smaller particles than the rectangular gap. The research results in this paper can help people understand and effectively control the influence of outdoor particles on the indoor air quality and provide reference data for the prediction of indoor particle mass concentration in buildings, which has theoretical basis and practical significance.


 
256 viewsCategory: Ecology
 
Sustainability, Vol. 12, Pages 1710: Experimental Analysis of a Novel PV/T Panel with PCM and Heat Pipes (Sustainability)
Sustainability, Vol. 12, Pages 1707: Integrating Sustainability in the Quality Assessment of EHEA Institutions: A Hybrid FDEMATEL-ANP-FIS Model (Sustainability)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Ecology


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten