MyJournals Home  

RSS FeedsIJERPH, Vol. 19, Pages 16417: Analysis of Thermal Insulation Thickness for a Container House in the Yanqing Zone of the Beijing 2022 Olympic and Paralympic Winter Games (International Journal of Environmental Research and Public Health)

 
 

7 december 2022 13:41:16

 
IJERPH, Vol. 19, Pages 16417: Analysis of Thermal Insulation Thickness for a Container House in the Yanqing Zone of the Beijing 2022 Olympic and Paralympic Winter Games (International Journal of Environmental Research and Public Health)
 


A large number of temporary housings (THs) were used in the Yanqing zone of the Beijing 2022 Olympic and Paralympic Winter Games. Taking a kind of container house (CH) used in Yanqing zone as a model, the objective of this paper is to analyze the effect of insulation thickness on heating energy consumption and corresponding carbon emission. The effect of service life of THs on economic thickness was also discussed. The simulation model was developed using EnergyPlus and the heating energy consumption with different insulation materials was simulated based on the meteorological parameters of the top of Xiaohaituo Mountain (2177.5 m) and the Olympic/Paralympic Village (950 m) in Yanqing zone. In the simulation process, the thermal insulation performance of the CH was enhanced with reference to the requirements of GB/T 51350-2019 Technical Standard for Nearly Zero Energy Buildings (NZEB) on one hand. Additionally, the insulation performance was evaluated in terms of payback period and carbon emission. On the other hand, the economic thickness of different insulation materials (rock wool (RW), extruded polystyrene (XPS), polyurethane (PU)) and the high performance vacuum insulation panel (HVIP)) for different service lives of CH was studied. Results show that the U-values of the envelope meeting the NZEB standard can decrease approximately 21.4–32.8% of the heating energy consumption, compared with the original envelope. When the service life of CH is extended to 20 years, the carbon emission is reduced by 18.5% and 29.5%. The payback period of HVIP is longest, up to 31.4 a, and the results of economic thickness show that when the service life of the CH ranges from 1 year to 20 years, the economic thickness range of RW is 47–235 mm, XPS is 41–197 mm, PU is 33–149 mm and HVIP is 4–18 mm at the altitude of 2177.5 m. At the altitude of 950 m, the economic thickness range of RW is 28–158 mm, XPS is 26–131 mm, PU is 25–118 mm, and HVIP is 2–12 mm. From an economic point of view, the service life of a CH has a significant impact on the choice of insulation thickness.


 
95 viewsCategory: Medicine, Pathology, Toxicology
 
IJERPH, Vol. 19, Pages 16418: Screening for Referral of Serious Pathology by Physical Examination Tests in Patients with Back or Chest Pain: A Systematic Review (International Journal of Environmental Research and Public Health)
IJERPH, Vol. 19, Pages 16416: Development and Psychometric Validation of the Athletes’ Perceived Body Pressures from Coaches Questionnaire (APBPCQ) (International Journal of Environmental Research and Public Health)
 
 
blog comments powered by Disqus


MyJournals.org
The latest issues of all your favorite science journals on one page

Username:
Password:

Register | Retrieve

Search:

Toxicology


Copyright © 2008 - 2024 Indigonet Services B.V.. Contact: Tim Hulsen. Read here our privacy notice.
Other websites of Indigonet Services B.V.: Nieuws Vacatures News Tweets Nachrichten